MP3300iec 7851 views
Up to 32 Axes
The MP3300iec is the newest member of the MPiec series. It offers:
Open standards EtherNet/IP, Modbus/TCP and others for connectivity to many peripheral devices on the market.
IEC61131-3 means that programs are developed and executed with predictable behavior.
The controller can operate local Sigma-5 outputs. This reduces panel cost and space requirements when just a couple of outputs are necessary.
The MECHATROLINK motion network provides a channel for configuring the machine from a single location with one software tool.
Choose from eight option cards offered for the expansion slots to accommodate most machine requirements.
Use Yaskawa's VIPA SLIO EtherNet/P modules to meet all your remote I/O needs. Numerous third-party remote I/Os such as Phoenix, Wago, and Opto 22 can also be interfaced with the system via MECHATROLINK and Ethernet.
A built in web server offers standard controller diagnostic information eliminating the need for special software for maintenance personnel
Item |
Specifications |
|
MP3300iec |
||
Classification |
Controller |
|
Name |
MP3300iec |
|
Model Number |
PMC-U-MP33004 (Standard Performance). CPU module, MP3300iec, 4-axis PMC-U-MP33008 (Standard Performance). CPU module, MP3300iec, 8-axis PMC-U-MP33020 (Standard Performance). CPU module, MP3300iec, 20-axis PMC-U-MP33320 (Medium Performance). CPU module, MP3300iec, 20-axis PMC-U-MP33332 (Medium Performance). CPU module, MP3300iec, 32-axis |
|
Supported Modules |
LIO-01, LIO-02, LIO-04, LIO-05, LIO-06, AI-01, AO-01, DO-01 |
|
Software |
MotionWorks IEC Express MotionWorks IEC Pro |
|
CPU |
400 MHz or 800 MHz |
|
Number of option module slots |
1, 3 or 8 |
|
User Variable Memory |
32 MB |
|
Power Unit |
Input Voltage |
24VDC |
Input Current |
1.0 A max (at rated input/output) for 1 slot module 1.5 A max (at rated input/output) for 3 slots module |
|
Battery |
Battery for memory retention attachable at the bottom of the CPU unit |
|
Motion Network |
MECHATROLINK-III: 1 channel, 2 connectors SERVOPACK and I/O for up to 20 slave nodes connectable (SERVOPACK for up to 20 axes) Baud rate: 100 Mbps (MECHATROLINK-III) |
|
Communication Function |
Ethernet: 10Base-T or 100Base-TX |
|
Ethernet Protocols |
Ethernet/IP and Modbus TCP/IP standard on all units, User specific protocols can be written using Y_DeviceComm firmware library |
|
Calendar |
Seconds, minutes, hour, day, week, month, year, day of week, and timing (battery backup) |
|
Environmental Conditions |
Ambient Operating Temperature |
0°C to 60°C (Forced cooling is required if 55°C is exceeded.) |
Ambient Storage Temperature |
-25°C to 85°C |
|
Ambient Operating Humidity |
10% to 95% RH (with no condensation) |
|
Ambient Storage Humidity |
10% to 95% RH (with no condensation) |
|
Pollution Level |
Conforms to JIS B 3502 Pollution Degree 2 |
|
Corrosive Gas |
There must be no combustible or corrosive gas |
|
Operating Altitude |
2,000 m above sea level or lower |
|
Mechanical Conditions |
Vibration Resistance |
Conforming to JIS B 3502:
|
Shock Resistance |
Size of shock: Peak acceleration of 147 m/s2 (15 G) Duration: 11ms 3 times each in the X, Y, and Z directions |
|
Electrical Operating Conditions |
Noise Resistance |
Conforming to EN 61000-6-2, EN 61000-6-4 and EN 55011 (Group 1, Class A) Power supply noise (FT noise): 2Kv min., for one minute Radiation noise (FT noise): 1Kv min., for one minute Ground noise (impulse noise): 1kV min., for 10 minutes Electrostatic noise (contact discharge method): 6 kV or more, 10 times |
Installation Requirements |
Ground |
Ground to 100 Ω max. |
Cooling Method |
Natural cooling or forced-air cooling |
|
Connectors |
M-III: MECHATROLINK, 2 connectors Ethernet: RJ 45: Ethernet RLY OUT: RLY OUT connector USB: DUSB-ARA42-T11A-FA (DDK), type A connector |
|
Indicators |
RDY(green), RUN(green), ALM(red), ERR(red), BAT(red), M-ALM(red) |
|
Switches |
STOP, E-INIT, INIT, CNFG, LOAD, TEST and MNT |
|
Dimensions |
64 mm X 130 mm X 108 mm (W × H × D) with 1 slot module 120 mm X 130 mm X 108 mm (W × H × D) with 3 slots module |